Dimensioning Guidelines for Drawing Creation |
|||
Guidelines |
Drawing Levels |
||
Standard |
Mixed |
Functional Design with Analysis |
|
Drawing indicates all the dimensioning and tolerancing standards that apply |
X |
X |
X |
The drawing fully defines each surface of the part (for size, location, orientation or form) |
X |
X |
X |
No coordinate tolerances are used to locate holes, tabs, or slots |
X |
X |
X |
Position tolerances are used to locate all holes (also slots and tabs) |
X |
X |
X |
Profile tolerances are used to locate part surfaces |
X |
X |
X |
Orientation tolerances are used to orient all angular relationships |
X |
X |
X |
Datum(s) are specified |
X |
X |
X |
All geometric tolerances are specified in accordance with Y14.5 |
X |
X |
X |
All general notes, title block tolerances, and notes show clear definition and do not conflict with other tolerances |
X |
X |
X |
General tolerances are specified for non-functional (or non-critical) part features with geometric tolerances that are mathematically robust |
X |
X |
X |
All part features assemble at nominal |
|
X |
X |
The dimensioning is based on a combination of functional dimensioning, dimensioning for manufacturing, and/or inspection (organization must define the mix) |
|
X |
x |
Tolerance stacks exist to ensure part assembly at worst case |
P |
X |
|
Part tolerances are adjusted based on tolerance stacks for assembly |
|
X |
|
Dimensioning is based on the function of the part |
P |
X |
|
Part mounting features should be used as datum features; additional datum features are specified to document functional relationships. |
P |
X |
|
Part functions are identified and prioritized |
P |
X |
|
A functional analysis has been completed for each part |
X |
||
Where a part feature affects several product functions, the dimensioning represents at least one of them |
X |
||
All important functional part feature relationships are directly dimensioned using GD&T |
X |
||
Design has been adjusted to ensure that tolerance values are maximized and based on product function |
X |
||
The stacks that ensure product function have been completed |
X |
||
A tolerance stack exists for each tolerance (for a functional relationship) on the drawing |
X |
||
P = Begin to work on this guideline as much as practical X = Use this guideline on new drawings |
|||